C2C
ENERGY
Live snapshotUpdated 0s ago · automatic every 60s
Sign in
04 / Health

Cells, temps, protections.

Alerts

2 unacknowledged

Storage

Battery packs

0/9 packs fresh
Battery bank
no reading · unknown · 11.5 kWh lifepo4 · no SOC source: add packs, a shunt, or a hybrid that reports SOC
Blue = neutral reading, amber = dashboard warning, red = fresh reported BMS protection. No battery-health score. Voltage and charging/discharging safety limits are not verified here.
Battery 1
Last read 4h ago
95%
-0.37 A
Cell spread1.0 mV
0 mV▲ warn ≥ 30 mV60 mV
4/4 reported cells · current max − min, not history · dashboard warning
Sensor 165.5 °F
-40 °F▲ warn ≥ 120 °F140 °F
18.6 °C · Dashboard warning, not BMS cutoff; charge/discharge limits unknown
Stale
Battery 2
Last read 4h ago
97%
-0.38 A
Cell spread5.0 mV
0 mV▲ warn ≥ 30 mV60 mV
4/4 reported cells · current max − min, not history · dashboard warning
Sensor 165.7 °F
-40 °F▲ warn ≥ 120 °F140 °F
18.7 °C · Dashboard warning, not BMS cutoff; charge/discharge limits unknown
Stale
Battery 3
Last read 4h ago
98%
-0.38 A
Cell spread6.0 mV
0 mV▲ warn ≥ 30 mV60 mV
4/4 reported cells · current max − min, not history · dashboard warning
Sensor 166.0 °F
-40 °F▲ warn ≥ 120 °F140 °F
18.9 °C · Dashboard warning, not BMS cutoff; charge/discharge limits unknown
Stale
Battery 4
Last read 4h ago
96%
-0.37 A
Cell spread5.0 mV
0 mV▲ warn ≥ 30 mV60 mV
4/4 reported cells · current max − min, not history · dashboard warning
Sensor 166.2 °F
-40 °F▲ warn ≥ 120 °F140 °F
19.0 °C · Dashboard warning, not BMS cutoff; charge/discharge limits unknown
Stale
Battery 5
Last read 4h ago
96%
-0.37 A
Cell spread2.0 mV
0 mV▲ warn ≥ 30 mV60 mV
4/4 reported cells · current max − min, not history · dashboard warning
Sensor 166.6 °F
-40 °F▲ warn ≥ 120 °F140 °F
19.2 °C · Dashboard warning, not BMS cutoff; charge/discharge limits unknown
Stale
Battery 6
Last read 4h ago
98%
-0.38 A
Cell spread2.0 mV
0 mV▲ warn ≥ 30 mV60 mV
4/4 reported cells · current max − min, not history · dashboard warning
Sensor 166.7 °F
-40 °F▲ warn ≥ 120 °F140 °F
19.3 °C · Dashboard warning, not BMS cutoff; charge/discharge limits unknown
Stale
Battery 7
Last read 4h ago
97%
-0.38 A
Cell spread5.0 mV
0 mV▲ warn ≥ 30 mV60 mV
4/4 reported cells · current max − min, not history · dashboard warning
Sensor 167.1 °F
-40 °F▲ warn ≥ 120 °F140 °F
19.5 °C · Dashboard warning, not BMS cutoff; charge/discharge limits unknown
Stale
Battery 8
Last read 4h ago
98%
-0.38 A
Cell spread2.0 mV
0 mV▲ warn ≥ 30 mV60 mV
4/4 reported cells · current max − min, not history · dashboard warning
Sensor 167.3 °F
-40 °F▲ warn ≥ 120 °F140 °F
19.6 °C · Dashboard warning, not BMS cutoff; charge/discharge limits unknown
Stale
Battery 9
Never read
Cell spread
0 mV▲ warn ≥ 30 mV60 mV
4/4 reported cells · current max − min, not history · dashboard warning
Sensor 1
-40 °F▲ warn ≥ 120 °F140 °F
— °C · Dashboard warning, not BMS cutoff; charge/discharge limits unknown
Stale
Cell voltages and temperatures come straight from each pack's BMS sample. Warnings here are display thresholds (30 mV spread, 120 °F); the BMS enforces its own limits.